stk/Help/focus.n.html

103 lines
5.0 KiB
HTML

<HTML><HEAD><TITLE>Tk Built-In Commands - focus manual page</TITLE></HEAD>
<BR>
<BODY bgcolor = #c3c3ff>
<H2><IMG ALIGN=BOTTOM SRC="./Img/ManPageBlue.gif"> focus</H2>
<I>Manage the input focus</I><P><IMG ALIGN=TOP SRC="./Img/line-red.gif">
<H3><A NAME="M2">SYNOPSIS</A></H3>
(<B>focus</B>)<BR>
(<B>focus </B><I>window</I>)<BR>
(<B>focus </B><I>option</I> ?<I>arg arg ...</I>?)<BR>
<H3><A NAME="M3">DESCRIPTION</A></H3>
The <B>focus</B> procedure is used to manage the Tk input focus.
At any given time, one window on each display is designated as
the <I>focus window</I>; any key press or key release events for the
display are sent to that window.
It is normally up to the window manager to redirect the focus among the
top-level windows of a display. For example, some window managers
automatically set the input focus to a top-level window whenever
the mouse enters it; others redirect the input focus only when
the user clicks on a window.
Usually the window manager will set the focus
only to top-level windows, leaving it up to the application to
redirect the focus among the children of the top-level.
<P>
Tk remembers one focus window for each top-level (the most recent
descendant of that top-level to receive the focus); when the window
manager gives the focus
to a top-level, Tk automatically redirects it to the remembered
window. Within a top-level Tk uses an <I>explicit</I> focus model
by default. Moving the mouse within a top-level does not normally
change the focus; the focus changes only when a widget
decides explicitly to claim the focus (e.g., because of a button
click), or when the user types a key such as Tab that moves the
focus.
<P>
The STk procedure <B>Tk:focus-follows-mouse</B> may be invoked to
create an <I>implicit</I> focus model: it reconfigures Tk so that
the focus is set to a window whenever the mouse enters it.
The STk procedures <B>Tk:focus-next</B> and <B> Tk:focus-prev</B>
implement a focus order among the windows of a top-level; they
are used in the default bindings for Tab and Shift-Tab, among other
things.
<P>
The <B>focus</B> procedure can take any of the following forms:
<P>
<DL>
<DT><A NAME="M4">(<B>focus</B>)</A><DD>
Returns the path name of the focus window on the display containing
the application's main window, or <B>#f</B> if no window in
this application has the focus on that display. Note: it is
better to specify the display explicitly using <B>:displayof</B>
(see below) so that the code will work in applications using multiple
displays.
<P>
<DT><A NAME="M5">(<B>focus </B><I>window</I>)</A><DD>
If the application currently has the input focus on <I>window</I>'s
display, this procedure resets the input focus for <I>window</I>'s display
to <I>window</I> and returns an empty string.
If the application doesn't currently have the input focus on
<I>window</I>'s display, <I>window</I> will be remembered as the focus
for its top-level; the next time the focus arrives at the top-level,
Tk will redirect it to <I>window</I>.
If <I>window</I> is an empty string then the procedure does nothing.
<P>
<DT><A NAME="M6">(<B>focus :displayof</B> <I>window</I>)</A><DD>
Returns the name of the focus window on the display containing <I>window</I>.
If the focus window for <I>window</I>'s display isn't in this
application, the return value is an empty list.
<P>
<DT><A NAME="M7">(<B>focus :force </B><I>window</I>)</A><DD>
Sets the focus of <I>window</I>'s display to <I>window</I>, even if
the application doesn't currently have the input focus for the display.
This procedure should be used sparingly, if at all.
In normal usage, an application should not claim the focus for
itself; instead, it should wait for the window manager to give it
the focus.
If <I>window</I> is an empty string then the procedure does nothing.
<P>
<DT><A NAME="M8">(<B>focus :lastfor</B> <I>window</I>)</A><DD>
Returns the name of the most recent window to have the input focus
among all the windows in the same top-level as <I>window</I>.
If no window in that top-level has ever had the input focus, or
if the most recent focus window has been deleted, then the name
of the top-level is returned. The return value is the window that
will receive the input focus the next time the window manager gives
the focus to the top-level.
<P>
</DL>
<H3><A NAME="M9">QUIRKS</A></H3>
When an internal window receives the input focus, Tk doesn't actually
set the X focus to that window; as far as X is concerned, the focus
will stay on the top-level window containing the window with the focus.
However, Tk generates FocusIn and FocusOut events just as if the X
focus were on the internal window. This approach gets around a
number of problems that would occur if the X focus were actually moved;
the fact that the X focus is on the top-level is invisible unless
you use C code to query the X server directly.
<H3><A NAME="M10">SEE ALSO</A></H3>
<B><A HREF="./grab.n.html">grab</A></B>
<P><IMG ALIGN=TOP SRC="./Img/line-red.gif"><P>
<A HREF=./STk-hlp.html><IMG ALIGN=BOTTOM SRC="./Img/RefBookBlue.gif"> Back to the <B>STk</B> main page</A>
</BODY></HTML>